PWC-01
Modular Hot-Swappable Online UPS
APC Symmetra/Galaxy, Vertiv Liebert Trinergy/EXM, and Eaton 93PM modular UPS systems allowing live 20kW–50kW power module swaps with zero downtime.
Request SpecificationEliminate the #1 and #2 causes of data center outages—power failures and thermal overheating. Dulo Tech engineers dual-bus 2N electrical distribution, hot-swappable modular UPS arrays, prime-rated sync generators, and low-PUE precision in-row/perimeter cooling.
2N POWER & PRECISION HVAC // < 1.32 PUE
East African utility grids experience frequent voltage sags, harmonic spikes, phase imbalances, and extended blackouts—while tropical ambient temperatures challenge conventional cooling systems.
Dulo Tech engineers resilient 2N electrical chains (from dual MV transformers and prime-rated diesel generators with automatic transfer switches down to hot-swappable modular Lithium-Ion/VRLA UPS frames and metered rack PDUs) paired with N+1 precision cooling that maintains strict ASHRAE TC 9.9 thermal envelopes.
We design, supply, and maintain six core electrical and mechanical subsystems.
PWC-01
APC Symmetra/Galaxy, Vertiv Liebert Trinergy/EXM, and Eaton 93PM modular UPS systems allowing live 20kW–50kW power module swaps with zero downtime.
Request Specification
PWC-02
Vertiv Liebert, Schneider Uniflair, and Stulz inverter-driven precision CRAC/CRAH and In-Row coolers coupled directly to hot-aisle heat loads.
Request Specification
PWC-03
Synchronized Cummins/Perkins acoustic diesel generators, motorized Automatic Transfer Switches (ATS), and Static Transfer Switches (STS < 4ms).
Request Specification
PWC-04
Long-life Lithium-Ion (LiFePO4) and high-rate VRLA battery banks equipped with per-cell impedance, voltage, and temperature BMS monitoring.
Request Specification
PWC-05
Dual A/B color-coded (Red/Blue) metered and switched IP PDUs with per-outlet power metering, environmental probes, and locking IEC cords.
Request Specification
PWC-06
Servo/static Automatic Voltage Regulators (AVRs), Type 1+2 surge protection devices (SPDs), active harmonic filters, and < 1 Ohm clean IT earthing pits.
Request SpecificationCooling typically consumes 40% of a legacy server room's electricity. We slash that waste through six engineering upgrades.
Replacing fixed-speed AC units with inverter compressors and EC fans that modulate power draw dynamically with real-time server load.
Preventing cold supply air from mixing with hot exhaust air so supply temperatures can be safely raised to ASHRAE 22–24°C.
Placing cooling coils directly between server racks to shorten airflow paths from 15 meters down to 1.5 meters.
Utilizing 97%–99% efficient silicon-carbide (SiC) double-conversion and eConversion UPS topologies.
Sealing every unused rack U-space and cable floor cutout to stop cold plenum pressure loss.
Installing Class-1 kWh meters on utility incoming feeds and IT UPS outputs to track live Power Usage Effectiveness (PUE) in DCIM.
Technical design parameters enforced across Dulo Tech power and cooling deployments.
| Parameter Code | Subsystem Domain | Engineering Standard | Redundancy Topology | Target Operating Metric |
|---|---|---|---|---|
| MEP-01 | Utility & Generator Entry | IEC 61439 / IEEE 446 | Dual Transformer + N+1 Sync Gen | < 10 Sec Generator Pick-Up |
| MEP-02 | UPS & Battery Autonomy | IEC 62040-3 (VFI-SS-111) | 2N Dual Bus or N+1 Modular | 15–60 Min Full-Load Battery Runtime |
| MEP-03 | Rack Power Distribution | TIA-942 / IEC 60309 | Dual A+B Switched IP PDUs | Balanced < 40% Max Per-Bus Load (2N) |
| MEP-04 | Thermal & Humidity Envelope | ASHRAE TC 9.9 (Class A1) | N+1 or 2N In-Row / CRAC | 18–27°C Inlet / 45–55% Relative Humidity |
| MEP-05 | Clean Earthing & Surge | IEEE 1100 / BS 7430 | Dedicated Equipotential Mesh | < 1.0 Ohm Earth Resistance |
Direct answers from Dulo Tech Limited's Principal Systems Architects, CSOC Directors, and Institutional Procurement Officers at Mirage Towers, Nairobi.
Routed directly to our Senior Engineering Board at 12th Floor, Mirage Towers, Westlands, Nairobi.
Excellence in Enterprise ICT, Cybersecurity, Supply & Tier-IV Data Center Engineering across Africa.
Currently Available: Tech Advisory, ICT & Software Supply, 24/7 CSOC & VAPT, Deep-Tech R&D, Managed Support & Data Center Builds.